DESCRIPTION:
The IDT49C466/A 64-bit Flow-thruEDC is a high-speed error detection and correction unit that ensures data integrity in memory systems. The flow-thru architecture, with separate system and memory data buses, is ideally suited for pipelined memory systems.
FEATURES:
⢠64-bit wide Flow-thruEDCï
⢠Separate System and Memory Data Input/Output Buses
⢠â Error Detect Time: 10ns â Error Correct Time: 15ns
⢠Corrects all single bit errors; Detects all double bit errors and some multiple bit errors
⢠Configurable 16-deep bus read/write FIFOs with flags
⢠Simultaneous check bit generation and correction of memory data
⢠Supports partial word writes on byte boundaries
⢠Low noise output
⢠Sophisticated error diagnostics and error logging
⢠Parity generation on system data bus
⢠208-pin Plastic Quad Flatpack
|