PIC18F66K80 FAMILY
TABLE 31-1: MEMORY PROGRAMMING REQUIREMENTS
DC CHARACTERISTICS
Standard Operating Conditions
Operating temperature -40°C TA +85°C for Industrial
-40°C TA +125°C for Extended
Param
No.
Sym
Characteristic
Min
Typ† Max Units
Conditions
Internal Program Memory
Programming Specifications(1)
D110 VPP Voltage on MCLR/VPP/RE5 pin VDD + 1.5 —
D113 IDDP Supply Current during
Programming
10
V (Note 3, Note 4)
10 mA
D120
D121
ED
VDRW
Data EEPROM Memory
Byte Endurance
VDD for Read/Write
D122 TDEW Erase/Write Cycle Time
D123 TRETD Characteristic Retention
D124 TREF Number of Total Erase/Write
Cycles before Refresh(2)
(Note 2)
100K 1000K — E/W -40C to +125C
1.8
5.5
V Using EECON to read/write
PIC18FXXKXX devices
1.8
3.6
V Using EECON to read/write
PIC18LFXXKXX devices
4
ms
20
— Year Provided no other
specifications are violated
1M
10M
— E/W -40°C to +125°C
Program Flash Memory
D130 EP Cell Endurance
1K
10K
— E/W -40C to +125C
D131 VPR VDD for Read
1.8
5.5
V PIC18FXXKXX devices
1.8
3.6
V PIC18LFXXKXX devices
D132B VPEW Voltage for Self-Timed Erase or
Write Operations
VDD
1.8
5.5
V PIC18FXXKXX devices
D133A TIW Self-Timed Write Cycle Time
2
ms
D134 TRETD Characteristic Retention
20
— Year Provided no other
specifications are violated
D135 IDDP Supply Current during
Programming
10 mA
D140 TWE Writes per Erase Cycle
1
For each physical address
† Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. These parameters are for design guidance
only and are not tested.
Note 1:
2:
3:
4:
These specifications are for programming the on-chip program memory through the use of table write
instructions.
Refer to Section 8.8 “Using the Data EEPROM” for a more detailed discussion on data EEPROM
endurance.
Required only if Single-Supply Programming is disabled.
The MPLAB® ICD 2 does not support variable VPP output. Circuitry to limit the ICD2 VPP voltage must be
placed between the ICD 2 and target system when programming or debugging with the ICD2.
DS39977F-page 558
2010-2012 Microchip Technology Inc.

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]