Symbol
Parameter
IDD
(Shutdown)
Supply current in
Shutdown mode
(backup
registers
retained) RTC
disabled
Table 47. Current consumption in Shutdown mode
Conditions
TYP
-
VDD 0 °C 25 °C 40 °C 55 °C 85 °C 105 °C
1.8 V 0.039 0.013 0.030 0.100 0.635 1.950
2.4 V 0.059 0.014 0.055 0.120 0.785 2.350
-
3.0 V 0.064 0.037 0.070 0.180 1.000 2.900
3.6 V 0.071 0.093 0.140 0.280 1.300 3.700
IDD
(Shutdown
with RTC)
Supply current in
Shutdown mode
(backup
registers
retained) RTC
enabled
RTC clocked
by LSE
quartz (2) in low
drive mode
1.8 V
2.4 V
3.0 V
3.6 V
0.320
0.425
0.535
0.695
0.315 0.355 0.420 0.985
0.405 0.460 0.540 1.200
0.535 0.595 0.700 1.500
0.720 0.790 0.940 2.000
2.300
2.800
3.450
4.350
0 °C
-
-
-
-
-
-
-
-
MAX(1)
Unit
25 °C 85 °C 105 °C
- 2.099 6.200
-
-
-
0.185 2.670 7.490
0.247 3.120 8.450
µA
0.572 2.702 6.180
-
-
-
0.664 2.990 7.800
0.790 3.730 9.140
1. Guaranteed by characterization results, unless otherwise specified.
2. Based on characterization done with a 32.768 kHz crystal (MC306-G-06Q-32.768, manufacturer JFVNY) with two 6.8 pF loading capacitors.
Table 48. Current consumption in VBAT mode
Symbol Parameter
Conditions
TYP
MAX(1)
Unit
-
VBAT 0 °C 25 °C 40 °C 55 °C 85 °C 105 °C 0 °C 25 °C 40 °C 55 °C 85 °C 105 °C
1.8 V 1.00 2.00 4.00 10.0 52.0 145 -
-
-
-
-
-
2.4 V 1.00 2.00 5.00 12.0 60.0 165 -
-
-
-
-
RTC disabled
Backup
3.0 V 2.00 4.00 7.00 16.0 75.0 225 -
-
-
-
-
IDD(VBAT)
domain
supply
current
3.6 V 7.00 15.0 23.0 42.0 170 450
RTC enabled 1.8 V 295 305 315 325 380 480
and clocked 2.4 V 385 395 400 415 475 595
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
by LSE
quartz(2)
3.0 V 495 505 515 530 600 765 -
-
-
-
-
3.6 V 630 645 660 685 830 1150 -
-
-
-
-
-
-
-
nA
-
-
-
-
1. Guaranteed by characterization results, unless otherwise specified.
2. Based on characterization done with a 32.768 kHz crystal (MC306-G-06Q-32.768, manufacturer JFVNY) with two 6.8 pF loading capacitors.