TLU.240.
Vishay Telefunken
Optical and Electrical Characteristics
Tamb = 25_C, unless otherwise specified
Red (TLUR240. )
Parameter
Luminous intensity
Dominant wavelength
Peak wavelength
Angle of half intensity
Forward voltage
Reverse voltage
Junction capacitance
Test Conditions
Type Symbol Min Typ Max Unit
IF = 10 mA, IVmin/IVmax ≥ 0.5 TLUR2400 IV
TLUR2401 IV
IF = 10 mA
ld
IF = 10 mA
lp
IF = 10 mA
ϕ
IF = 20 mA
VF
IR = 10 mA
VR
VR = 0, f = 1 MHz
Cj
0.4 0.8
mcd
1 1.5 5 mcd
645
nm
660
nm
±20
deg
1.6 2 V
6 15
V
50
pF
Orange red (TLUO240. )
Parameter
Luminous intensity
Dominant wavelength
Peak wavelength
Angle of half intensity
Forward voltage
Reverse voltage
Junction capacitance
Test Conditions
Type Symbol Min Typ Max Unit
IF = 10 mA, IVmin/IVmax ≥ 0.5 TLUO2400 IV
1.6 2
mcd
TLUO2401 IV
4 5 20 mcd
IF = 10 mA
ld 612
625 nm
IF = 10 mA
lp
630
nm
IF = 10 mA
ϕ
±20
deg
IF = 20 mA
VF
23V
IR = 10 mA
VR
6 15
V
VR = 0, f = 1 MHz
Cj
50
pF
Yellow (TLUY240. )
Parameter
Luminous intensity
Dominant wavelength
Peak wavelength
Angle of half intensity
Forward voltage
Reverse voltage
Junction capacitance
Test Conditions
Type Symbol Min Typ Max Unit
IF = 10 mA, IVmin/IVmax ≥ 0.5 TLUY2400 IV
14
mcd
TLUY2401 IV 2.5 8 12.5 mcd
IF = 10 mA
ld 581
594 nm
IF = 10 mA
IF = 10 mA
lp
585
nm
ϕ
±20
deg
IF = 20 mA
IR = 10 mA
VF
2.4 3 V
VR
6 15
V
VR = 0, f = 1 MHz
Cj
50
pF
Green (TLUG240. )
Parameter
Luminous intensity
Dominant wavelength
Peak wavelength
Angle of half intensity
Forward voltage
Reverse voltage
Junction capacitance
Test Conditions
Type Symbol Min Typ Max Unit
IF = 10 mA, IVmin/IVmax ≥ 0.5 TLUG2400 IV
TLUG2401 IV
IF = 10 mA
ld
IF = 10 mA
lp
IF = 10 mA
ϕ
IF = 20 mA
VF
IR = 10 mA
VR
VR = 0, f = 1 MHz
Cj
1.6 5
mcd
4 12 20 mcd
562
575 nm
565
nm
±20
deg
2.4 3 V
6 15
V
50
pF
www.vishay.de • FaxBack +1-408-970-5600
2 (8)
Document Number 83053
Rev. A1, 04-Feb-99