5.Test
No change on display and in operation under the following test condition.
Conditions:
Unless otherwise specified, tests will be conducted under the following condition.
Temperature: 20±5°C
Humidity : 65±5%RH
tests will be not conducted under functioning state.
No.
Parameter
Conditions
1
High Temperature Operating 50°C±2°C, 96hrs (operation state)
2
Low Temperature Operating 0°C±2°C, 96hrs (operation state)
3
High Temperature Storage
70°C±2°C, 96hrs
4
Low Temperature Storage
-20°C±2°C, 96hrs
5
Damp Proof Test
40°C±2°C,90~95%RH, 96hrs
6
Temperature Cycle Test
5 Cycle
1 Cycle
Notes
1
2
1,2
1,2
2
7
Shock Test
70°C
25°C
-20° C
30Min 10Min 30Min 10Min
The function test shall be conducted after
1
hours storage at the normal temperature and
To be measured after dropping from 60cm high on
the concrete surface in packing state.
E
B
Dropping method corner dropping
F
A corner : once
GD C
Edge dropping
B,C,D edge : once
A
Face dropping
60cm
E,F,G face : once
Concrete Surface
Note 1 :It should be checked at the actual driving condition under the high temperature.
Note 2 :No dew condensation to be observed.
Note 3 :The function test shall be conducted after 4 hours storage at the normal
temperature and humidity after removed from the test chamber.
Note 4 :Vibration test will be conducted to the product itself without putting it in a ontainer.
Note 5 :No air bubbles and no color variation on display more than 24 hours after the test.
F-51320GNF-S-AD (AD) No. 2002-0148
OPTREX CORPORATION
Page 17/23