ELECTRICAL SPECIFICATIONS
Table 4-11. ISA Bus AC Timing
Name Parameter
Min
64e
IOW# negated to write data invalid
1T
64f
MEMW# negated to copy data float, 8-bit ISA Slave, odd Byte
by ISA Master
1T
64g
IOW# negated to copy data float, 8-bit ISA Slave, odd Byte by
ISA Master
1T
Note: The signal numbering refers to Table 4-7
Max
Units
Cycles
Cycles
Cycles
Release 1.3 - January 29, 2002
47/87