POWER SUPPLY OPERATIONAL MODES
Standard Operational Modes
Table 109 - Standard Operational Modes For The Power Supplies.
MODE
VBAT
VTR
VCC
RTC Only (1)
3.3V
0
0
Standby (2) (3)
3.3V
5V @ 2mA Max
0
Full Power (2)
3.3V
5V @ 2mA Max
5V
Note 1: RTC power supplied by Vbat
Note 2: RTC power supplied by VTR
Note 3: In standby mode, the following are operational: RTC, RTC Alarm 2, power control (wakeup)
logic (button input and power on) and soft power management logic.
When VCC goes away, certain registers will be powered by VTR. Similarly, when VTR goes away,
certain registers will be powered by Vbat. These registers are discussed in the Soft Power
Management and RTC Section.
Power Supply Non-Standard Modes
Table 110 - Non-Standard Operational Modes For The Power Supplies.
NON-STANDARD MODE
VBAT
VTR
VCC
NS1
0
5V @ 2mA Max
0
NS2
0
5V @ 2mA Max
5V
NS3
0
0
5V
NS4
3.3V
0
5V