DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

STM32F405IGY7TR View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
STM32F405IGY7TR Datasheet PDF : 185 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
STM32F405xx, STM32F407xx
Description
Table 4. Timer feature comparison (continued)
Timer
type
Timer
Counter
resolutio
n
Counter
type
Prescaler
factor
DMA
request
generatio
n
Capture/
compare
channels
Complementar
y output
Max
interface
clock
(MHz)
Max
timer
clock
(MHz)
TIM2,
TIM5
32-bit
Up,
Down,
Up/dow
n
Any integer
between 1
and 65536
Yes
4
TIM3,
TIM4
16-bit
Up,
Down,
Up/dow
n
Any integer
between 1
and 65536
Yes
4
Any integer
General TIM9 16-bit
Up between 1
No
2
purpose
and 65536
TIM10
Any integer
,
16-bit
Up between 1
No
1
TIM11
and 65536
Any integer
TIM12 16-bit
Up between 1
No
2
and 65536
TIM13
Any integer
,
16-bit
Up between 1
No
1
TIM14
and 65536
No
42
84
No
42
84
No
84
168
No
84
168
No
42
84
No
42
84
Basic
TIM6,
TIM7
16-bit
Any integer
Up between 1
Yes
and 65536
0
No
42
84
Advanced-control timers (TIM1, TIM8)
The advanced-control timers (TIM1, TIM8) can be seen as three-phase PWM generators
multiplexed on 6 channels. They have complementary PWM outputs with programmable
inserted dead times. They can also be considered as complete general-purpose timers.
Their 4 independent channels can be used for:
Input capture
Output compare
PWM generation (edge- or center-aligned modes)
One-pulse mode output
If configured as standard 16-bit timers, they have the same features as the general-purpose
TIMx timers. If configured as 16-bit PWM generators, they have full modulation capability (0-
100%).
The advanced-control timer can work together with the TIMx timers via the Timer Link
feature for synchronization or event chaining.
TIM1 and TIM8 support independent DMA request generation.
DocID022152 Rev 4
31/185

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]