I²C and RF command sets
M24SR02-Y
5.7.2
Table 39 defines the R-APDU of the Verify command.
Data
Table 39. R-APDU of the Verify command
SW1
SW2
Comment
Length
Value
Value
Value
Value
Value
Value
Value
Value
-
1 byte
1 byte -
-
0x90
0x00 Command completed, the password is correct
-
0x69
0x85
The conditions of use are not satisfied (e.g. no
NDEF file was selected)
-
0x69
0x81 Cmd incompatible with file structure
-
0x69
0x82 Security status not satisfied
-
0x6A
0x80 Incorrect parameter in cmd data field
-
0x63
0x00 A password is required
-
0x63
0xCX (1)
The password transmitted is incorrect and X
encodes the number of further allowed retries.
-
0x6E
0x00 Class not supported
1. At each session, the RF host can check a password 3 times.
Change Reference Data command
The Change Reference Data command replaces the read or write password related to the
NDEF files previously selected. It can be performed only if the security status satisfies the
security attributes for this command.
Before sending this command, the verify command with the correct NDEF write password
shall be issued. Thus, this command changes the reference data of the NDEF file.
Table 40 defines the Change Reference Data command.
Table 40. Change reference data command format
Name
CLA
INS
P1 & P2
Lc
Data
Le
0x00
0x24
2 bytes
1 byte
Lc bytes
-
Class byte
Instruction code
Password identification
0x0001: Read password transmit
0x0002: Write password transmit
0x0003: I²C password transmit (1)
Other: RFU
0x10: the password is present in the data field
NDEF file or I²C Password
-
1. This code can only be issued by the I²C host.
44/90