Characteristics
1
Characteristics
STPS3150
Table 2.
Symbol
Thermal resistance
Parameter
Rth(j-l) Junction to lead
Lead length = 10 mm
SMB flat
SMB
DO-201AD
Value
10
20
15
Unit
° C/W
Table 3. Static electrical characteristics
Symbol
Parameter
Tests conditions
Min. Typ Max.
Unit
IR (1) Reverse leakage current
Tj = 25° C
Tj = 125° C
VR = VRRM
0.4 2.0
µA
0.6 2.0
mA
VF (2) Forward voltage drop
Tj = 25° C
Tj = 125° C
Tj = 25° C
Tj = 125° C
IF = 3 A
IF = 6 A
0.78 0.82
0.63 0.67
V
0.85 0.89
0.70 0.75
1. tp = 5 ms, δ < 2%
2. tp = 380 µs, δ < 2%
To evaluate the conduction losses use the following equation:
P = 0.59 x IF(AV) + 0.023 IF2(RMS)
Figure 1.
Average forward power
dissipation versus average
forward current
PF(AV)(W)
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0.0
0.0
0.5
δ = 0.05
δ = 0.1
δ = 0.2
δ = 0.5
δ=1
T
IF(AV)(A)
δ=tp/T
tp
1.0
1.5
2.0
2.5
3.0
3.5
Figure 2.
Average forward current versus
ambient temperature (δ = 0.5)
(DO-201AD / SMB)
IF(AV)(A)
3.5
3.0
Rth(j-a)=Rth(j-I)
DO-201AD
2.5
SMB
2.0
1.5
Rth(j-a)=75°C/W
1.0
0.5
0.0
0
T
δ=tp/T
25
tp
50
Tamb(°C)
75
100
125
150
175
2/10