DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

AD5170BRM2.5-RL7(RevA) View Datasheet(PDF) - Analog Devices

Part Name
Description
Manufacturer
AD5170BRM2.5-RL7
(Rev.:RevA)
ADI
Analog Devices 
AD5170BRM2.5-RL7 Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
AD5170
I2C INTERFACE
Table 7. Write Mode
S 0 1 0 1 1 AD1 AD0 W A 2T SD T 0 OW X X X A D7 D6 D5 D4 D3 D2 D1 D0 A P
Slave Address Byte
Instruction Byte
Data Byte
Table 8. Read Mode
S 0 1 0 1 1 AD1 AD0 R A D7 D6 D5 D4 D3 D2 D1 D0 A E1 E0 X X X X X X A P
Slave Address Byte
Instruction Byte
Data Byte
S = Start Condition.
P = Stop Condition.
A = Acknowledge.
AD0, AD1 = Package Pin Programmable Address Bits.
X = Don’t Care.
W = Write.
R = Read.
2T = Second fuse link array for two-time programming. Logic 0
corresponds to first trim. Logic 1 corresponds to second trim.
Note that blowing trim #2 before trim #1 effectively disables
trim #1 and in turn only allows one-time programming.
SD = Shutdown connects wiper to B terminal and open circuits
the A terminal. It does not change the contents of the wiper
register.
T = OTP Programming Bit. Logic 1 permanently programs the
wiper.
OW = Overwrite the fuse setting and program the digital
potentiometer to a different setting. Note that upon power-up,
the digital potentiometer presets to either midscale or fuse
setting depending on whether the fuse link has been blown.
D7, D6, D5, D4, D3, D2, D1, D0 = Data Bits.
E1, E0 = OTP Validation Bits.
0, 0 = Ready to Program.
1, 0 = Fatal Error. Some fuses not blown. Do not retry.
Discard this unit.
1, 1 = Programmed Successfully. No further adjustments are
possible.
Rev. A | Page 18 of 24