AD565A
ABSOLUTE MAXIMUM RATINGS
VCC to Power Ground . . . . . . . . . . . . . . . . . . . . . 0 V to +18 V
VEE to Power Ground (AD565A) . . . . . . . . . . . . 0 V to –18 V
Voltage on DAC Output (Pin 9) . . . . . . . . . . . . –3 V to +12 V
Digital Inputs (Pins 13 to 24) to
Power Ground . . . . . . . . . . . . . . . . . . . . . . –1.0 V to +7.0 V
REF IN to Reference Ground . . . . . . . . . . . . . . . . . . . . ± 12 V
Bipolar Offset to Reference Ground . . . . . . . . . . . . . . . ± 12 V
10 V Span R to Reference Ground . . . . . . . . . . . . . . . . ± 12 V
20 V Span R to Reference Ground . . . . . . . . . . . . . . . . ± 24 V
REF OUT (AD565A) . . . . . Indefinite Short to Power Ground
Momentary Short to VCC
Power Dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 mW
GROUNDING RULES
The AD565A and AD566A use separate reference and power
grounds to allow optimum connections for low noise and high
speed performance. These grounds should be tied together at one
point, usually the device power ground. The separate ground
returns minimize current flow in low level signal paths. In this
way, logic return currents are not summed into the same return
path with analog signals.
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection. Although the
AD565A/AD566A features proprietary ESD protection circuitry, permanent damage may occur on
devices subjected to high energy electrostatic discharges. Therefore, proper ESD precautions are
recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE
–6–
REV.F