Preliminary Technical Data
Figure 21 shows the connections of the ADE7752B analog
inputs with the power lines in a 3-phase 3-wire delta service.
Ra* Cf
Rb*
VR*
PHASE A
Rb*
CT
VAP
IAP
IAN
ANTIALIASING
FILTERS
SOURCE
PHASE B
PHASE C
CT
VN
Rf
Cf
LOAD
Ra* Cf
Rb*
VR*
ANTIALIASING
FILTERS
Rb*
IBP
IBN
VBP
* Ra >> Rf + VR; * Rb + VR = Rf
Figure 21. 3-Phase 3-Wire Meter Connection with ADE7752B
Note that only two current inputs and two voltage inputs of the
ADE7752B are used in this case. The active power calculated by
the ADE7752B does not depend on the selected channels.
ADE7752B
Figure 22 shows the connections of the ADE7752B analog
inputs with the power lines in a 3-phase 4-wire Wye service.
Ra* Cf
Rb*
VR*
VA P
IAP
Rb*
CT
IAN
ANTIALIASING
FILTERS
PHASE A
SOURCE
PHASE B
PHASE C
Ra* Cf
Rb*
VR*
CT
CT
ANTIALIASING
Rb*
FILTERS
IBP
IBN
VBP
Ra* Cf
Rb*
VR*
Rf
VN
ANTIALIASING
FILTERS
Rb*
ICP LOAD
ICN
VCP
CF
* Ra >> Rf + VR; * Rb + VR = Rf
Figure 22. 3-Phase 4-Wire Meter Connection with ADE7752B
Rev. PrA | Page 17 of 27