QUICK START
This section outlines the procedure for powering up and initializing
the ADE7816. Figure 23 shows a flow diagram of the initialization
steps. For detailed information, refer to the section of the data
sheet that pertains to each step, as indicated in Figure 23.
Data Sheet
After power is supplied to the ADE7816 and communication
is established, a set of registers must be written (see Figure 23).
Table 8 lists details about each register.
The registers listed in Table 8 are essential for correct operation.
After these registers are set, enable any meter-specific features
before enabling the DSP to begin the energy calculations.
WTHR1 = 0x000002
WTHR0 = 0x000000
VARTHR1 = 0x000002
VARTHR0 = 0x000000
PCF_A_COEFF = 0x400CA4 (50Hz)
PCF_B_COEFF = 0x400CA4 (50Hz)
PCF_C_COEFF = 0x400CA4 (50Hz)
PCF_D_COEFF = 0x400CA4 (50Hz)
PCF_E_COEFF = 0x400CA4 (50Hz)
PCF_F_COEFF = 0x400CA4 (50Hz)
DICOEFF = 0xFFF8000
POWER UP THE
ADE7816
(SEE POWER AND
GROUND SECTION)
SET AND LOCK
COMMUNICATION MODE
(SEE COMMUNICATION
SECTION)
WRITE REQUIRED
REGISTER
DEFAULTS
CONFIGURE METER
SPECIFIC INTERRUPTS,
POWER QUALITY
FEATURES, AND
CALIBRATE
(SEE THE INTERRUPTS,
POWER QUALITY
FEATURES, AND ENERGY
CALIBRATION SECTIONS)
ENABLE THE ENERGY
METERING DSP
(SEE STARTING AND
STOPPING THE DSP
SECTION)
NOTE THAT THE FINAL
REGISTER SHOULD BE
WRITTEN 3 TIMES TO
CLEAR THE BUFFER
(SEE STARTING AND
STOPPING THE DSP
SECTION)
INITIALIZATION
COMPLETE
Figure 23. Quick Start
Table 8. Required Register Defaults
Register Register
Address Name
Register Description
0x43AB WTHR1
Threshold register for active energy
0x43AC WTHR0
Threshold register for active energy
0x43AD VARTHR1
Threshold register for reactive energy
0x43AE VARTHR0
Threshold register for reactive energy
0x43B1 PCF_A_COEFF Phase calibration for Current Channel A
0x43B2 PCF_B_COEFF Phase calibration for Current Channel B
0x43B3 PCF_C_COEFF Phase calibration for Current Channel C
0x43B4 PCF_D_COEFF Phase calibration for Current Channel D
0x43B5 PCF_E_COEFF Phase calibration for Current Channel E
0x43B6 PCF_F_COEFF Phase calibration for Current Channel F
0x4388 DICOEFF
Digital integrator algorithm; required only
if using di/dt sensors
Required Value
0x000002
0x000000
0x000002
0x000000
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0x400CA4 (50 Hz)
0xFFF8000
Reference Information
Refer to the Active Energy Threshold section.
Refer to the Active Energy Threshold section.
Refer to the Reactive Energy Threshold section.
Refer to the Reactive Energy Threshold section.
Refer to the Energy Phase Calibration section.
Refer to the Energy Phase Calibration section.
Refer to the Energy Phase Calibration section.
Refer to the Energy Phase Calibration section.
Refer to the Energy Phase Calibration section.
Refer to the Energy Phase Calibration section.
Refer to the Digital Integrator section.
Rev. 0 | Page 16 of 48

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]