PRECISION HIGH CURRENT VOLTAGE SOURCE
In some cases, the user may want higher output current delivered
to a load and still achieve better than 0.5% accuracy from the
ADR380/ADR381. The accuracy for a reference is normally
specified on the data sheet with no load. However, the output
voltage changes with load current.
The circuit in Figure 30 provides high current without compromis-
ing the accuracy of the ADR380/ADR381. By op amp action,
VOUT follows VREF with very low drop in R1. To maintain circuit
equilibrium, the op amp also drives the N-Channel MOSFET
Q1 into saturation to maintain the current needed at different
loads. R2 is optional to prevent oscillation at Q1. In such an
approach, hundreds of milliamps of load current can be achieved,
and the current is limited by the thermal limitation of Q1. VIN =
VOUT + 300 mV.
ADR380/ADR381
VIN
R1
100kΩ
8V TO 15V
C1
0.001µF
Q1
1
VIN
2
VOUT
+V
A1
–V
AD820
2N7002
R2
100Ω
U1
ADR380/
RL
ADR381
GND
3
VOUT
Figure 30. ADR380/ADR381 for Precision High Current Voltage Source