34.1.3 rev. A/B
XMEGA D4
• Bandgap voltage input for the ACs can not be changed when used for both ACs simultaneously
• VCC voltage scaler for AC is non-linear
• ADC gain stage cannot be used for single conversion
• ADC has increased INL error for some operating conditions
• ADC gain stage output range is limited to 2.4 V
• ADC Event on compare match non-functional
• ADC propagation delay is not correct when 8x -64x gain is used
• Bandgap measurement with the ADC is non-functional when VCC is below 2.7V
• Accuracy lost on first three samples after switching input to ADC gain stage
• Configuration of PGM and CWCM not as described in XMEGA D Manual
• PWM is not restarted properly after a fault in cycle-by-cycle mode
• BOD: BOD will be enabled at any reset
• Sampled BOD in Active mode will cause noise when bandgap is used as reference
• EEPROM page buffer always written when NVM DATA0 is written
• Pending full asynchronous pin change interrupts will not wake the device
• Pin configuration does not affect Analog Comparator Output
• NMI Flag for Crystal Oscillator Failure automatically cleared
• Flash Power Reduction Mode can not be enabled when entering sleep
• Crystal start-up time required after power-save even if crystal is source for RTC
• RTC Counter value not correctly read after sleep
• Pending asynchronous RTC-interrupts will not wake up device
• TWI Transmit collision flag not cleared on repeated start
• Clearing TWI Stop Interrupt Flag may lock the bus
• TWI START condition at bus timeout will cause transaction to be dropped
• TWI Data Interrupt Flag (DIF) erroneously read as set
• WDR instruction inside closed window will not issue reset
• Inverted I/O enable does not affect Analog Comparator Output
• TWIE is not available
• CRC generator module is not available
• ADC 1/x gain setting and VCC/2 reference setting is not available
• TOSC alternate pin locations is not available
• TWI SDAHOLD time configuration is not available
• Timer/Counter 2 is not available
• HIRES+ option is not available
• Alternate pin locations for digital peripherals are not available
• XOSCPWR high drive option for external crystal is not available
• PLL divide by two option is not available
• Real Time Counter non-prescaled 32 kHZ clock options are not available
• PLL lock detection failure function is not available
• Non available functions and options
8135L–AVR–06/12
1. Bandgap voltage input for the ACs cannot be changed when used for both ACs
simultaneously
120