dsPIC30F3014/4013
TABLE 23-17: AC CHARACTERISTICS: INTERNAL RC ACCURACY
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature
-40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Characteristic
Min Typ Max Units
Conditions
Internal FRC Jitter @ FRC Freq. = 7.37 MHz(1)
OS62 FRC
— +0.04 +0.16 %
— +0.07 +0.23 %
FRC with 4x PLL
— +0.31 +0.62 %
— +0.34 +0.77 %
FRC with 8x PLL
— +0.44 +0.87 %
— +0.48 +1.08 %
FRC with 16x PLL
— +0.71 +1.23 %
Internal FRC Accuracy @ FRC Freq. = 7.37 MHz(1)
OS63 FRC
—
— +1.50 %
Internal FRC Drift @ FRC Freq. = 7.37 MHz(1)
OS64
-0.7
—
0.5
%
-0.7
—
0.7
%
-0.7
—
0.5
%
-0.7
—
0.7
%
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +125°C
-40°C ≤ TA ≤ +85°C
-40°C ≤ TA ≤ +125°C
VDD = 3.0-3.6V
VDD = 4.5-5.5V
VDD = 3.0-3.6V
VDD = 4.5-5.5V
VDD = 3.0-3.6V
VDD = 4.5-5.5V
VDD = 4.5-5.5V
VDD = 3.0-5.5V
VDD = 3.0-3.6V
VDD = 3.0-3.6V
VDD = 4.5-5.5V
VDD = 4.5-5.5V
Note 1:
2:
Frequency calibrated at 7.372 MHz ±2%, 25°C and 5V. TUN bits (OSCCON<3:0>) can be used to
compensate for temperature drift.
Overall FRC variation can be calculated by adding the absolute values of jitter, accuracy and drift
percentages.
TABLE 23-18: AC CHARACTERISTICS: INTERNAL RC JITTER
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Characteristic
Min Typ Max Units
Conditions
LPRC @ Freq. = 512 kHz(1)
OS65
-35
—
+35
%
—
Note 1: Change of LPRC frequency as VDD changes.
© 2007 Microchip Technology Inc.
DS70138E-page 177