dsPIC30F3014/4013
TABLE 23-34: I2C BUS DATA TIMING REQUIREMENTS (MASTER MODE) (CONTINUED)
AC CHARACTERISTICS
Standard Operating Conditions: 2.5V to 5.5V
(unless otherwise stated)
Operating temperature -40°C ≤ TA ≤ +85°C for Industrial
-40°C ≤ TA ≤ +125°C for Extended
Param
No.
Symbol
Characteristic
Min(1)
Max Units
Conditions
IM21
TR:SCL SDA and SCL
Rise Time
100 kHz mode
400 kHz mode
1 MHz mode(2)
—
20 + 0.1 CB
—
1000
300
300
ns CB is specified to be
ns from 10 to 400 pF
ns
IM25 TSU:DAT Data Input
100 kHz mode
250
—
ns
—
Setup Time
400 kHz mode
100
—
ns
1 MHz mode(2)
TBD
—
ns
IM26 THD:DAT Data Input
100 kHz mode
0
—
ns
—
Hold Time
400 kHz mode
0
0.9
μs
1 MHz mode(2)
TBD
—
ns
IM30 TSU:STA Start Condition 100 kHz mode TCY/2 (BRG + 1) —
Setup Time
400 kHz mode TCY/2 (BRG + 1) —
1 MHz mode(2) TCY/2 (BRG + 1)
—
μs Only relevant for
μs repeated Start
μs condition
IM31 THD:STA Start Condition 100 kHz mode TCY/2 (BRG + 1) —
Hold Time
400 kHz mode TCY/2 (BRG + 1) —
1 MHz mode(2) TCY/2 (BRG + 1)
—
μs After this period the
μs first clock pulse is
μs generated
IM33 TSU:STO Stop Condition 100 kHz mode TCY/2 (BRG + 1) —
μs
—
Setup Time
400 kHz mode TCY/2 (BRG + 1) —
μs
1 MHz mode(2) TCY/2 (BRG + 1)
—
μs
IM34 THD:STO Stop Condition 100 kHz mode TCY/2 (BRG + 1) —
ns
—
Hold Time
400 kHz mode TCY/2 (BRG + 1) —
ns
1 MHz mode(2) TCY/2 (BRG + 1)
—
ns
IM40 TAA:SCL Output Valid
100 kHz mode
—
3500
ns
—
From Clock
400 kHz mode
—
1000
ns
—
1 MHz mode(2)
—
—
ns
—
IM45
TBF:SDA Bus Free Time
100 kHz mode
400 kHz mode
1 MHz mode(2)
4.7
1.3
TBD
—
μs Time the bus must be
—
μs free before a new
—
μs transmission can start
IM50 CB
Bus Capacitive Loading
—
400
pF
Note 1: BRG is the value of the I2C Baud Rate Generator. Refer to Section 21 “Inter-Integrated Circuit™ (I2C)”
in the “dsPIC30F Family Reference Manual” (DS70046).
2: Maximum pin capacitance = 10 pF for all I2C pins (for 1 MHz mode only).
© 2007 Microchip Technology Inc.