DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LA05-PB(2005) View Datasheet(PDF) - LEM Industrial

Part Name
Description
Manufacturer
LA05-PB
(Rev.:2005)
LEM
LEM Industrial 
LA05-PB Datasheet PDF : 3 Pages
1 2 3
Current Transducer LA 03..20-PB
For the electronic measurement of currents: DC, AC, pulsed, mixed,
with a galvanic isolation between the primary circuit (high power) and
the secondary circuit (electronic circuit).
IPN =
3 .. 20 A
Electrical data
Primary nominal
r.m.s. current 1)
I
PN
(A)
3
5
10
15
20
Primary current,
measuring range
I
P
(A)
± 4.5
± 7.5
± 15
± 22.5
± 30
Primary Current
Limitation 3)
(A)
3
3
5
7.5
10
Primary Conductor
Diameter
(mm)
0.5
0.5
0.65
0.8
1.0
Type
LA 03-PB
LA 05-PB
LA 10-PB
LA 15-PB
LA 20-PB
V
C
IC
R
IS
VOUT
RL
Supply voltage (± 5 %)
± 15
V
Current consumption
Isolation resistance @ 500 VDC
app. 20mA + IPN/1200mA
> 500
M
Output voltage @ ± IPN, RL = 10 k, TA = 25°C ± 4
V
Load resistance
> 10
k
Accuracy-Dynamic performance data
X
εL
V
OE
VOH
VOT
ε TC G
tr
f
Accuracy @ I , T = 25°C (without offset)
PN A
Linearity error (0 .. ± IPN)
Electrical offset voltage, T = 25°C
A
Hysteresis offset voltage @ IP = 0;
after an excursion of 1 x I
PN
Thermal drift of VOE (-10..+80°C)
(-20..-10°C)
<± 1.5
<± 1
<± 30
<± 15
<± 1
<± 2
Thermal drift of the gain (% of reading) (-10..+80°C) <± 0.04
(-20..-10°C) <± 0.08
Response time @ 90% of IP
Frequency bandwidth (- 1dB)2)
<3
DC .. 150
% of I
PN
% of IPN
mV
mV
mV/K
mV/K
%/K
%/K
µs
kHz
General data
TA
Ambient operating temperature
T
Ambient storage temperature
S
m
Mass
- 20 .. + 80
°C
- 30 .. + 85
°C
< 12
g
Features
Closed loop (compensation) current
transducer using the Hall effect
Voltage output
Printed circuit board mounting
Advantages
Excellent accuracy
Very good linearity
Low temperature drift
Optimized response time
Wide frequency bandwidth
No insertion losses
High immunity to external
interference
Current overload capacity
Applications
AC variable speed drives and servo
motor drives
Static converters for DC motor drives
Battery supplied applications
Uninterruptible Power Supplies
(UPS)
Switched Mode Power Supplies
(SMPS)
Power supplies for welding
applications
Notes : 1) Calibration for 4V output is carried out at the primary norminal r.m.s.
current.
2) Derating is needed to avoid excessive core heating at high frequency.
3) Primary current is limited by primary wire size. Permanent primary
current should not exceed the specified value.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.
LEM Industrial
051102/6
Page 1/3
www.lem.com