DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LTC4156IUFD View Datasheet(PDF) - Linear Technology

Part Name
Description
Manufacturer
LTC4156IUFD Datasheet PDF : 52 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
OPERATION
Table 18. External Power (Wall or USB) Available
EXTERNAL POWER (WALL OR USB) AVAILABLE
SUB ADDRESS 0x04
EXT_PWR_GOOD
DIRECTION
Read
POWER AVAILABLE
STATUS
D7 D6 D5 D4 D3 D2
Battery Power
Only
0
External Power
Available*
1
*Never true when On-The-Go step-up converter is active.
REG4
D1 D0
Table 19. USB Input Voltage Valid
USB INPUT VOLTAGE VALID
REG4
SUB ADDRESS
0x04
USBSNS_GOOD
DIRECTION
Read
USBSNS STATUS
D7 D6 D5 D4 D3 D2 D1 D0
USBSNS Voltage
Invalid
0
USBSNS Voltage
Valid*
1
*Will be true with applied input voltage within valid range or On-The-Go
in regulation.
Table 20. WALL Input Voltage Valid
WALL INPUT VOLTAGE VALID
SUB ADDRESS 0x04
WALLSNS_GOOD
DIRECTION
Read
WALLSNS STATUS D7 D6 D5 D4 D3 D2
WALLSNS Voltage
Invalid
0
WALLSNS Voltage
Valid
1
REG4
D1 D0
Table 21. Input Current Limit Status
INPUT CURRENT LIMIT STATUS
REG4
SUB ADDRESS
0x04
AT_INPUT_ILIM
DIRECTION
Read
INPUT CURRENT
LIMIT STATUS
D7 D6 D5 D4 D3 D2 D1 D0
Input Current Limit Inactive
0
Input Current Limit Active
1
LTC4156
Table 22. Input Undervoltage Current Limit (Brownout) Status
INPUT UNDERVOLTAGE CURRENT LIMIT
(BROWNOUT) STATUS
REG4
SUB ADDRESS
0x04
INPUT_UVCL_ACTIVE
DIRECTION
Read
INPUT UNDERVOLTAGE
CURRENT LIMIT STATUS D7 D6 D5 D4 D3 D2 D1 D0
Input UVCL Inactive
0
Input UVCL Active
1
Table 23. Overvoltage Protection Fault
OVERVOLTAGE PROTECTION FAULT
SUB ADDRESS
0x04
OVP_ACTIVE
DIRECTION
Read
INPUT OVERVOLTAGE D7 D6 D5 D4 D3 D2
No Fault
0
Input (USB or WALL)
Overvoltage
1
REG4
D1 D0
Table 24. USB On-The-Go Step-Up Regulator Fault Shutdown
USB On-The-Go STEP-UP REGULATOR FAULT SHUTDOWN REG4
SUB ADDRESS
0x04
OTG_FAULT
DIRECTION
Read
STEP-UP
REGULATOR STATUS D7 D6 D5 D4 D3 D2 D1 D0
No Fault
0
Regulator Over
Current Shutdown
1
Table 25. Battery Unresponsive to Charging
BATTERY UNRESPONSIVE TO CHARGING
SUB ADDRESS
0x04
BAD_CELL
DIRECTION
Read
BATTERY STATUS
D7 D6 D5 D4 D3 D2
No Fault
Low Cell Voltage
Timeout
REG4
D1 D0
0
1
4156f
37

Share Link: 