M29F800DT
7
DC and AC parameters
DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 9: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 9.
Operating and AC measurement conditions
M29F800D
Parameter
55
70/ 90
Unit
Min
Max
Min
Max
VCC Supply voltage
4.5
5.5
4.5
5.5
V
Ambient Operating Temperature (range 1)
0
70
0
70
°C
Ambient Operating Temperature (range 6)
–40
85
–40
85
°C
Load capacitance (CL)
Input Rise and Fall times
Input Pulse voltages
Input and Output Timing Ref. voltages
30
10
0 to 3
1.5
100
pF
10
ns
0.45 to 2.4
V
0.8 and 2.0
V
Figure 8. AC measurement I/O waveform
High Speed (55ns)
3V
0V
1.5V
Standard (70, 90ns)
2.4V
0.45V
2.0V
0.8V
AI05276
27/53