Figure 16. Programmer Equipment Group Protect Flowchart
START
ADDRESS = GROUP ADDRESS
W = VIH
n=0
G, A9 = VID,
E = VIL
Wait 4µs
W = VIL
Wait 100µs
W = VIH
E, G = VIH,
A0, A2, A3 = VIL, A1 =VIH,
A6 =VIL, A9 = VID, Others = X
E = VIL
Wait 4µs
G = VIL
Wait 60ns
Read DATA
DATA NO
=
01h
YES
A9 = VIH
E, G = VIH
PASS
1. Block Protection Groups are shown in Appendix A, Tables 20 and 21.
++n NO
= 25
YES
A9 = VIH
E, G = VIH
FAIL
9 Part Numbering
AI11555
67/72