M41T82 M41T83
DC and ac parameters
Figure 24. Power down/up mode ac waveforms
VCC
VSO
tPD
SDA
SCL
DON'T CARE
trec
AI00596
Table 23. Power down/up trip points dc characteristics
Sym
Parameter(1) (2) (1,2)
Min Typ Max Unit
S
2.85 2.93 3.0
V
VRST Reset threshold voltage
R
2.55 2.63 2.7
V
Z
2.25 2.32 2.38
V
Battery back-up switchover
VSO
Hysteresis
VRST
V
25
mV
Reset Pulse width (VCC Rising)
140
280 ms
trec VCC to Reset Delay, VCC = (VRST + 100mV), falling to
(VRST – 100mV; for VCC slew rate of 10mV/µs
2.5
µs
1. All voltages referenced to VSS.
2. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.38 to 5.5V (except where noted).
49/58