DC and AC parameters
M41T93
Table 18. DC characteristics
Sym
Parameter
Test condition(1)
Min Typ
Operating voltage (S)
VCC Operating voltage (R)
Operating voltage (Z)
ILI Input leakage current
ILO Output leakage current
Supply current
ICC1 SCL = 0.1VCC/0.9VCC
SDO = Open
ICC2 Supply current (standby)
VIL Input low voltage
VIH Input high voltage
VOL Output low voltage
VOH
VBAT
Output high voltage
Pull-up supply voltage
(open drain)
Back-up supply voltage
IBAT Battery supply current
–40 to 85°C
3.00
–40 to 85°C
2.70
–40 to 85°C
2.38
0V ≤ VIN ≤ VCC
0V ≤ VOUT ≤ VCC
fSCL = 2MHz
fSCL = 5MHz
fSCL = 10MHz
E = VCC;
All inputs ≥ VCC – 0.2V;
≤ VSS + 0.2V
5.5V
3.0V
8
6.5
–0.3
RST, FT/RST
VCC/VBAT = 3.0V,
IOL = 1.0mA
SQW, IRQ/FT/OUT
VCC = 3.0V,
IOL = 1.0mA
SDO
VCC = 3.0V,
IOL = 3.0mA
VCC = 3.0V, IOH = –1.0mA (push-pull)
0.7VCC
2.4
IRQ/FT/OUT
25°C; VCC = 0V; OSC On; VBAT = 3V;
32kHz Off
1.8
365
1. Valid for Ambient Operating Temperature: TA = –40 to 85°C; VCC = 2.38V to 5.5V (except where noted).
Max Unit
5.50
V
5.50
V
5.50
V
±1
μA
±1
μA
0.5 mA
1.0 mA
2.0 mA
10
µA
µA
0.3VCC V
VCC+0.3 V
0.4
V
0.4
V
0.4
V
V
5.5
V
5.5
V
450 nA
38/51