DC and AC parameters
5
DC and AC parameters
M48T201Y, M48T201V
Note:
This section summarizes the operating and measurement conditions, as well as the DC and
AC characteristics of the device. The parameters in the following DC and AC characteristic
tables are derived from tests performed under the measurement conditions listed in
Table 11: DC and AC measurement conditions. Designers should check that the operating
conditions in their projects match the measurement conditions when using the quoted
parameters.
Table 11. DC and AC measurement conditions
Parameter
M48T201Y
M48T201V
Unit
VCC supply voltage
Ambient operating temperature
4.5 to 5.5
3.0 to 3.6
V
0 to 70
0 to 70
°C
Load capacitance (CL)
Input rise and fall times
100
50
pF
≤5
≤5
ns
Input pulse voltages
0 to 3
0 to 3
V
Input and output timing ref. voltages
1.5
1.5
V
Output High Z is defined as the point where data is no longer driven.
Figure 13. AC testing load circuit
DEVICE
UNDER
TEST
645Ω
CL = 100pF
1.75V
Note:
CL includes JIG capacitance
AI04764
Excluding open-drain output pin; 50 pF for M48T201V.
Table 12. Capacitance
Symbol
Parameter(1)(2)
Min
Max
CIN
Input capacitance
10
COUT(3)
Input/output capacitance
10
1. Effective capacitance measured with power supply at 5 V; sampled only, not 100% tested.
2. At 25°C; f = 1 MHz.
3. Outputs deselected.
Unit
pF
pF