M48T86
DC and AC parameters
Figure 14. Power down/up mode AC waveforms
VCC
4.5V
VPFD
VSO
tF
tR
trec
E
Table 13. Power down/up mode AC characteristics
Symbol
Parameter(1)
Min
Max
tF(2)
VCC fall time
300
tR
VCC rise time
100
trec
VPFD to E high
20
200
1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 4.5 to 5.5V (except where noted).
2. VCC fall time of less than tF may result in deselection/write protection not occurring until 200µs after VCC passes VPFD.
Table 14. Power down/up trip points DC characteristics
Symbol
Parameter(1)(2)
Min
Typ
VPFD Power-fail deselect voltage
4.0
VSO Battery back-up switchover voltage
3.0
tDR(3) Expected data retention time
10
1. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 4.5 to 5.5V (except where noted).
2. All voltages referenced to VSS.
3. At 25°C, VCC = 0V.
Max
4.35
AI01646
Unit
µs
µs
ms
Unit
V
V
YEARS
27/36