M48Z35AV
DC and AC parameters
Table 10. Power down/up trip points DC characteristics
Symbol
Parameter(1)(2)
Min
Typ
VPFD Power-fail deselect voltage
2.7
2.9
VSO
tDR(3)
Battery back-up switchover voltage
Expected data retention time
VPFD – 100mV
10
1. All voltages referenced to VSS.
2. Valid for ambient operating temperature: TA = 0 to 70°C; VCC = 3.0 to 3.6V (except where noted).
3. At 25°C, VCC = 0V.
Max
3.0
Unit
V
V
YEARS