M93S66, M93S56, M93S46
DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Table 5. Operating Conditions (M93Sx6)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
4.5
5.5
V
Ambient Operating Temperature (Device Grade 6)
–40
85
°C
TA
Ambient Operating Temperature (Device Grade 3)
–40
125
°C
Table 6. Operating Conditions (M93Sx6-W)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
2.5
5.5
V
TA
Ambient Operating Temperature (Device Grade 6)
–40
85
°C
Table 7. Operating Conditions (M93Sx6-R)
Symbol
Parameter
Min.
Max.
Unit
VCC
Supply Voltage
1.8
5.5
V
TA
Ambient Operating Temperature (Device Grade 6)
–40
85
°C
Table 8. AC Measurement Conditions (M93Sx6)
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Pulse Voltages
Input Timing Reference Voltages
Output Timing Reference Voltages
Note: Output Hi-Z is defined as the point where data out is no longer driven.
Min.
Max.
100
50
0.4 V to 2.4 V
1.0 V and 2.0 V
0.8 V and 2.0 V
Table 9. AC Measurement Conditions (M93Sx6-W and M93Sx6-R)
Symbol
Parameter
Min.
Max.
CL
Load Capacitance
100
Input Rise and Fall Times
50
Input Pulse Voltages
0.2VCC to 0.8VCC
Input Timing Reference Voltages
0.3VCC to 0.7VCC
Output Timing Reference Voltages
Note: Output Hi-Z is defined as the point where data out is no longer driven.
0.3VCC to 0.7VCC
Unit
pF
ns
V
V
V
Unit
pF
ns
V
V
V
17/34