MB81F643242C-60/-70/-10 Advanced Info (AE0.1E)
Burst
Length
2
4
8
Starting Column
Address
A2 A1 A0
XX0
XX1
X00
X01
X10
X11
000
001
010
011
100
101
110
111
Sequential Mode
0โ1
1โ0
0โ1โ2โ3
1โ2โ3โ0
2โ3โ0โ1
3โ0โ1โ2
0โ1โ2โ3โ4โ5โ6โ7
1โ2โ3โ4โ5โ6โ7โ0
2โ3โ4โ5โ6โ7โ0โ1
3โ4โ5โ6โ7โ0โ1โ2
4โ5โ6โ7โ0โ1โ2โ3
5โ6โ7โ0โ1โ2โ3โ4
6โ7โ0โ1โ2โ3โ4โ5
7โ0โ1โ2โ3โ4โ5โ6
Interleave
0โ1
1โ0
0โ1โ2โ 3
1โ0โ3โ2
2โ3โ0โ1
3โ2โ1โ0
0โ1โ2โ3โ4โ5โ6โ7
1โ0โ3โ2โ5โ4โ7โ6
2โ3โ0โ1โ6โ7โ4โ5
3โ2โ1โ0โ7โ6โ5โ4
4โ5โ6โ7โ0โ1โ2โ3
5โ4โ7โ6โ1โ0โ3โ2
6โ7โ4โ5โ2โ3โ0โ1
7โ6โ5โ4โ3โ2โ1โ0
FULL COLUMN BURST AND BURST STOP COMMAND (BST)
The full column burst is an option of burst length and available only at sequential mode of burst type. This full column
burst mode is repeatedly access to the same column. If burst mode reaches end of column address, then it wraps
round to first column address (= 0) and continues to count until interrupted by the news read (READ) /write (WRIT),
precharge (PRE), or burst stop (BST) command. The selection of Auto-precharge option is illegal during the full
column burst operation except write command at BURST READ & SINGLE WRITE mode.
The BST command is applicable to terminate the burst operation. If the BST command is asserted during the burst
mode, its operation is terminated immediately and the internal state moves to Bank Active.
When read mode is interrupted by BST command, the output will be in High-Z.
For the detail rule, please refer to โTIMING DIAGRAM - 8โ in section โs TIMING DIAGRAMSโ.
When write mode is interrupted by BST command, the data to be applied at the same time with BST command will
be ignored.
BURST READ & SINGLE WRITE
The burst read and single write mode provides single word write operation regardless of its burst length. In this
mode, burst read operation does not be affected by this mode.
18