MCP2140A
4.2 Timing Parameter Symbology and Load Conditions
The timing parameter symbols have been created following one of the following formats:
4.2.1 TIMING CONDITIONS
The temperature and voltages specified in Table 4-2 apply to all timing specifications, unless otherwise noted.
Figure 4-2 specifies the load conditions for the timing specifications.
TABLE 4-1: SYMBOLOGY
1. TppS2ppS
T
F
Frequency
E
Error
Lowercase letters (pp) and their meanings:
pp
io
Input or Output pin
rx
Receive
bitclk
RX/TX BITCLK
drt
Device Reset Timer
Uppercase letters and their meanings:
S
F
Fall
H
High
I
Invalid (high-impedance)
L
Low
2. TppS
T
Time
osc
tx
RST
Oscillator
Transmit
Reset
P
Period
R
Rise
V
Valid
Z
High-impedance
TABLE 4-2: AC TEMPERATURE AND VOLTAGE SPECIFICATIONS
Electrical Characteristics:
Standard Operating Conditions (unless otherwise stated):
AC Specifications
Operating temperature: -40°C ≤ TA ≤ +85°C (industrial)
Operating voltage VDD range as described in DC spec Section 4.1 “DC
Characteristicsâ€.
FIGURE 4-2:
LOAD CONDITIONS FOR DEVICE TIMING SPECIFICATIONS
Pin
CL
CL = 50 pF for all pins except OSC2
15 pF for OSC2 when external clock is used to drive OSC1
VSS
© 2007 Microchip Technology Inc.
DS22050A-page 33