MCP2140A
FIGURE 4-8:
RXPD/RXPDREF WAVEFORMS
BITCLK
RXPD
RXPDREF
Start Bit
IR110A
Data bit 7 Data bit 6 Data bit 5 Data bit ...
IR131A
IR132
IR132
IR132
IR132
IR132
IR132
0
1
0
0
1
0
Start Bit
Data bit 7 Data bit 6 Data bit 5 Data bit ...
RXPD
RXPDREF
IRD160
IRD161
TABLE 4-8: RXPD/RXPDREF REQUIREMENTS
AC Specifications
Electrical Characteristics:
Standard Operating Conditions (unless otherwise specified):
Operating Temperature: -40°C ≤ TA ≤ +85°C (industrial)
Operating Voltage VDD range is described in Section 4.1 “DC
Characteristicsâ€
Param.
No.
Sym
Characteristic
Min
Typ
Max Units
Conditions
IR110A TRXPDBIT Receive Baud Rate
384
IR132 TRXPDP RXPD/RXPDREF bit period (1)
—
IRD06 VRXPDDΔ Quiescent Delta Voltage
20
0
between RXPD and
RXPDREF
IRD06 VRXPDE IR Pulse Detect Delta Voltage
30
1
(RXPD to RXPDREF)
IR133 TRESP Response Time (2)
—
* These parameters characterized but not tested.
—
384
TOSC BAUD = 9600
8
—
TBITCLK
—
—
mV
—
—
mV RXPD signal must cross
RXPDREF signal level
—
600 *
ns
Note 1: TBITCLK = TRXBIT/16.
2: Response time measured with RXPDREF at (VDD - 1.5V)/2, while RXPD transitions from VSS to VDD.
© 2007 Microchip Technology Inc.
DS22050A-page 39