MCP4011/2/3/4
4.2 Power-up
When the device powers up (rising VDD crosses the
Trip Point Voltage (VTP)), the “default” wiper setting is
restored. Table 4-1 shows the default value loaded into
the wiper on POR/BOR.
TABLE 4-1: DEFAULT POR WIPER
SETTING SELECTION
Package
Code
Default
POR
Wiper
Setting
Wiper
Code
Typical
RAB Value
-202
-502
-103
-503
Mid-scale
1Fh
Mid-scale
1Fh
Mid-scale
1Fh
Mid-scale
1Fh
2.1 kΩ
5.0 kΩ
10.0 kΩ
50.0 kΩ
While VDD < Vmin (1.8V), the electrical performance
may not meet the data sheet specifications (see
Figure 4-2). The wiper state may be unknown. Also, the
device may be capable of incrementing or decrement-
ing, if a valid command is detected on the CS and U/D
pins.
4.3 Brown Out
If the device VDD is below the specified minimum
voltage, care must be taken to ensure that the CS and
U/D pins do not “create” any of the serial commands.
When the device VDD drops below VMIN (1.8V), the
electrical performance may not meet the data sheet
specifications (see Figure 4-2). The wiper state may be
unknown. Also, the device may be capable of
incrementing or decrementing, if a valid command is
detected on the CS and U/D pins.
When the device voltage rises from below the power-
up trip point (VTP) into the valid operation voltage
range, the wiper state will be forced to the default POR
wiper setting (see Table 4-1).
4.4 Serial Interface Inactive
The serial interface is inactive any time the CS pin is at
VIH and all write cycles are completed.
VDD
1.8V
VTP
VSS
FIGURE 4-2:
POR Trip Point (on Rising VDD)
Outside Device Operation
Wiper Forced to Default POR Setting
Power-up and Brown-out.
DS21978C-page 28
© 2006 Microchip Technology Inc.