ST72521M/R/AR
12.3.3 Auxiliary Voltage Detector (AVD) Thresholds
Subject to general operating condition for VDD, fCPU, and TA.
Symbol
VIT+(AVD)
VIT-(AVD)
Vhys(AVD)
∆VIT-
Parameter
1⇒0 AVDF flag toggle threshold
(VDD rise)
0⇒1 AVDF flag toggle threshold
(VDD fall)
AVD voltage threshold hysteresis
Voltage drop between AVD flag set
and LVD reset activated
Conditions
VD level = High in option byte
VD level = Med. in option byte
VD level = Low in option byte
VD level = High in option byte
VD level = Med. in option byte
VD level = Low in option byte
VIT+(AVD)-VIT-(AVD)
VIT-(AVD)-VIT-(LVD)
1. Data based on characterization results, not tested in production.
Min Typ
4.4 1)
4.6
Max Unit
4.9
Not Applicable
4.2
4.4 4.65 1) V
Not Applicable
200
mV
450
mV
12.3.4 External Voltage Detector (EVD) Thresholds
Subject to general operating condition for VDD, fCPU, and TA.
Symbol
Parameter
Conditions
VIT+(EVD)
VIT-(EVD)
Vhys(EVD)
1⇒0 AVDF flag toggle threshold
(VDD rise)1)
0⇒1 AVDF flag toggle threshold
(VDD fall)1)
EVD voltage threshold hysteresis
VIT+(EVD)-VIT-(EVD)
1. Data based on characterization results, not tested in production.
Min Typ Max Unit
1.15 1.26 1.35
V
1.1
1.2
1.3
200
mV
158/199