ST6200C/ST6201C/ST6203C
CONTROL PIN CHARACTERISTICS (Cont’d)
Figure 64. Typical Application with RESET pin 8)
VDD
VDD
EXTERNAL
RESET
CIRCUIT 7)
0.1µF 4.7kΩ
0.1µF
RESET
VDD
RPU
fINT
STOP MODE
INTERNAL
RESET
RESD1)
WATCHDOG RESET
LVD RESET
10.9.2 NMI Pin
Subject to general operating conditions for VDD, fOSC, and TA unless otherwise specified.
Symbol
Parameter
Conditions
Min
Typ 1)
Max
Unit
VIL
Input low level voltage 2)
VIH Input high level voltage 2)
Vhys Schmitt trigger voltage hysteresis 3)
0.7xVDD
200
400
Rpull-up Weak pull-up equivalent resistor 4)
VIN=VSS
VDD=5V
VDD=3.3V
40
80
100
200
0.3xVDD
V
mV
350
kΩ
700
Notes:
1. Unless otherwise specified, typical data are based on TA=25°C and VDD=5V.
2. Data based on characterization results, not tested in production.
3. Hysteresis voltage between Schmitt trigger switching levels. Based on characterization results, not tested.
4. The Rpull-up equivalent resistor is based on a resistive transistor. This data is based on characterization results, not
tested in production.
Figure 65. Typical Rpull-up vs. VDD with VIN=VSS
Rpull-up [Kohm]
300
250
200
150
100
50
3
Ta=-40°C
Ta=25°C
Ta=95°C
Ta=125°C
4
5
6
VDD [V]
82/100