DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

P1201SC62AP View Datasheet(PDF) - Teccor Electronics

Part Name
Description
Manufacturer
P1201SC62AP
Teccor-Electronics
Teccor Electronics 
P1201SC62AP Datasheet PDF : 212 Pages
First Prev 81 82 83 84 85 86 87 88 89 90 Next Last
TeleLink Fuse
TeleLink Fuse
The TeleLink Surface Mount (SM) surge resistant fuse offers circuit protection without
requiring a series resistor. When used in conjunction with the SIDACtor Transient Voltage
Suppressor (TVS), the TeleLink SM fuse and the SIDACtor TVS provide a complete
regulatory-compliant solution for standards such as GR 1089, TIA-968 (formerly known as
FCC Part 68), UL 60950, and ITU K.20 and K.21. No series resistor is required for the
F1250T and F1251T to comply with these standards.
Contact factory for enhanced K.20 and K.21 details.
Surge Ratings
TeleLink SM Fuse
F0500T
F1250T
F1251T
IPP
2x10 µs
Amps
not rated
500
500
IPP
10x160 µs
Amps
75
160
160
IPP
10x560 µs
Amps
45
115
115
IPP
10x1000 µs
Amps
35
100
100
Interrupting Values
TeleLink SM
Fuse
F0500T
F1250T
F1251T
Voltage
Rating
250 V
250 V
250 V
Current
Rating
500 mA
1.25 A
2A
I2t Measured
at DC Rated
Voltage
1.3 A2s
22.2 A2s
30 A2s
Voltage, Current
600 V, 40 A
600 V, 60 A *
600 V, 60 A *
Interrupting Rating
MIN
1 ms
1 ms
1 ms
TYP
2 ms
2 ms
2 ms
MAX
60 ms
60 ms
60 ms
* Interrupt test characterized at 50° to 70° phase angle. Phase angles approximating 90° may result in damage to the body of the fuse.
Notes:
• The TeleLink SM fuse is designed to carry 100% of its rated current for four hours and 250% of its rated current for one second
minimum and 120 seconds maximum. Typical time is four to 10 seconds. For optimal performance, an operating current of 80% or
less is recommended.
• I2t is a non-repetitive RMS surge current rating for a period of 16.7 ms.
Resistance Ratings
TeleLink SM Fuse
F0500T
F1250T
F1251T
Typical Voltage Drop
@ Rated Current
0.471 V
0.205 V
0.110 V
Notes:
• Typical inductance @ 4 µH up to 500 MHz.
• Resistance changes 0.5% for every °C.
• Resistance is measured at 10% rated current.
DC Cold Resistance
MIN
MAX
0.420 W
0.640 W
0.107 W
0.150 W
0.050 W
0.100 W
http://www.teccor.com
+1 972-580-7777
2 - 66
© 2002 Teccor Electronics
SIDACtor® Data Book and Design Guide

Share Link: 