TeleLink Fuse
Qualification Data
The F1250T and F1251T meet the following test conditions per GR 1089 without additional series resistance.
However, in-circuit test verification is required. Note that considerable heating may occur during Test 4 of the
Second Level AC Power Fault Test.
First Level Lightning Surge Test
Surge Voltage
Test
Volts
1
±600
2
±1000
3
±1000
4
±2500
5
±1000
Wave-form
µs
10x1000
10x360
10x1000
2x10
10x360
Surge Current
Amps
100
100
100
500
25
Repetitions Each
Polarity
25
25
25
10
5
Second Level Lightning Surge Test
Surge Voltage
Test
Volts
1
±5000
Wave-form
µs
2x10
Surge Current
Amps
500
Repetitions Each
Polarity
1
First Level AC Power Fault Test
Test
Applied Voltage, 60 Hz
VRMS
Short Circuit Current
Amps
Duration
1
50
0.33
15 min
2
100
0.17
15 min
3
200, 400, 600
1 at 600 V
60 applications, 1 s each
4
1000
1
60 applications, 1 s each
5
*
*
60 applications, 5 s each
6
600
0.5
30 s each
7
600
2.2
2 s each
8
600
3
1 s each
9
1000
5
0.5 s each
* Test 5 simulates a high impedance induction fault. For specific information, please contact Teccor Electronics.
Second Level AC Power Fault Test for Non-Customer Premises Equipment
Test
1
2
3
4
Applied Voltage, 60 Hz
VRMS
120, 277
600
600
100-600
Short Circuit Current
Amps
30
60
7
2.2 at 600 V
Duration
30 min
5s
5s
30 min
Notes:
• Power fault tests equal or exceed the requirements of UL 60950 3rd edition.
• Test 4 is intended to produce a maximum heating effect. Temperature readings can exceed 150 °C.
• Test 2 may be dependent on the closing angle of the voltage source. Fuse is characterized at 50° to 70°. Closing angles
approximating 90° may result in damage to the body of the fuse.