PIC16C77X
FIGURE 15-8: BANDGAP START-UP TIME
VBGAP
Enable Bandgap
Bandgap stable
TBGAP
VBGAP = 1.2V
TABLE 15-8 BANDGAP START-UP TIME
Parameter
No.
Sym Characteristic
Min
Typ†
Max Units
Conditions
36*
TBGAP Bandgap start-up time
—
30
TBD s Defined as the time between
the instant that the bandgap
is enabled and the moment
that the bandgap reference
voltage is stable.
*
These parameters are characterized but not tested.
†
Data in "Typ" column is at 5V, 25°C unless otherwise stated. These parameters are for design guidance only and are not
tested.
DS30275B-page 164