PIC18F2X1X/4X1X
TABLE 25-21: MASTER SSP I2C™ BUS DATA REQUIREMENTS
Param.
No.
Symbol
Characteristic
Min
Max Units
Conditions
100 THIGH Clock High Time 100 kHz mode 2(TOSC)(BRG + 1) — ms
400 kHz mode 2(TOSC)(BRG + 1) — ms
1 MHz mode(1) 2(TOSC)(BRG + 1) —
ms
101 TLOW Clock Low Time 100 kHz mode 2(TOSC)(BRG + 1) — ms
400 kHz mode 2(TOSC)(BRG + 1) — ms
1 MHz mode(1) 2(TOSC)(BRG + 1) —
ms
102 TR
SDA and SCL
Rise Time
100 kHz mode
400 kHz mode
1 MHz mode(1)
20 + 0.1 CB
1000
300
300
ns CB is specified to be from
ns 10 to 400 pF
ns
103 TF
SDA and SCL
Fall Time
100 kHz mode
400 kHz mode
1 MHz mode(1)
20 + 0.1 CB
300 ns CB is specified to be from
300 ns 10 to 400 pF
100 ns
90
TSU:STA Start Condition 100 kHz mode 2(TOSC)(BRG + 1) — ms Only relevant for
Setup Time
400 kHz mode 2(TOSC)(BRG + 1) —
1 MHz mode(1) 2(TOSC)(BRG + 1) —
ms Repeated Start
condition
ms
91
THD:STA Start Condition 100 kHz mode 2(TOSC)(BRG + 1) — ms After this period, the first
Hold Time
400 kHz mode 2(TOSC)(BRG + 1) —
ms clock pulse is generated
1 MHz mode(1) 2(TOSC)(BRG + 1) —
ms
106 THD:DAT Data Input
100 kHz mode
0
ns
Hold Time
400 kHz mode
0
0.9 ms
107 TSU:DAT Data Input
100 kHz mode
250
Setup Time
400 kHz mode
100
ns (Note 2)
ns
92
TSU:STO Stop Condition 100 kHz mode 2(TOSC)(BRG + 1) — ms
Setup Time
400 kHz mode 2(TOSC)(BRG + 1) — ms
1 MHz mode(1) 2(TOSC)(BRG + 1) —
ms
109 TAA
Output Valid
from Clock
100 kHz mode
400 kHz mode
1 MHz mode(1)
3500 ns
1000 ns
ns
110 TBUF Bus Free Time 100 kHz mode
4.7
— ms Time the bus must be free
400 kHz mode
1.3
ms before a new transmission
can start
D102 CB
Bus Capacitive Loading
400 pF
Note 1: Maximum pin capacitance = 10 pF for all I2C pins.
2: A Fast mode I2C bus device can be used in a Standard mode I2C bus system, but parameter 107 250 ns
must then be met. This will automatically be the case if the device does not stretch the LOW period of the
SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit
to the SDA line, parameter 102 + parameter 107 = 1000 + 250 = 1250 ns (for 100 kHz mode), before the
SCL line is released.
© 2007 Microchip Technology Inc.
Preliminary
DS39636C-page 345