TOP242-250
Key Application Considerations
TOPSwitch-II vs. TOPSwitch-GX
Table 4 compares the features and performance differences
between TOPSwitch-GX and TOPSwitch-II. Many of the new
features eliminate the need for additional discrete components.
Other features increase the robustness of design allowing cost
savings in the transformer and other power components.
Function
TOPSwitch-II TOPSwitch-GX Figures TOPSwitch-GX Advantages
Soft-Start
N/A*
External Current Limit N/A*
DCMAX
67%
Line Feed Forward with N/A*
DCMAX Reduction
Line OV Shutdown
N/A*
Line UV Detection
N/A*
Switching Frequency
Switching Frequency
Option (Y, R and F
Packages)
100 kHz ±10%
N/A*
Frequency Jitter
N/A*
Frequency Reduction N/A*
10 ms
Programmable
100% to 30% of
default current
limit
11,20,21,
24,25,27,
28,34,35,
38,39
78%
7
78% to 38%
Single resistor
programmable
Single resistor
programmable
132 kHz ±6%
66 kHz ±7%
7,11,17,
26,27,28,
31,40
11,17,19,
26,27,28,
31,33,40
11,17,18,
26,27,28,
31,32,40
13,15
14,15
±4 kHz@132 kHz 9,46
±2 kHz@66 kHz
At a Duty Cycle 7
below 10%
• Limits peak current and voltage
component stresses during start-up
• Eliminates external components
used for soft-start in most
applications
• Reduces or eliminates output
overshoot
• Smaller transformer
• Higher efficiency
• Allows power limiting (constant over-
load power independent of line
voltage
• Allows use of larger device for lower
losses, higher efficiency and smaller
heatsink
• Smaller input cap (wider dynamic
range)
• Higher power capability (when used
with RCD clamp for large V )
OR
• Allows use of Schottky secondary
rectifier diode for up to 15 V output
for high efficiency
• Rejects line ripple
• Increases voltage withstand cap-
ability against line surge
• Prevents auto-restart glitches
during power down
• Smaller transformer
• Below start of conducted EMI limits
• Lower losses when using RC and
RCD snubber for noise reduction in
video applications
• Allows for higher efficiency in
standby mode
• Lower EMI (second harmonic below
150 kHz)
• Reduces conducted EMI
• Zero load regulation without dummy
load
• Low power consumption at no load
Table 4. Comparison Between TOPSwitch-II and TOPSwitch-GX. (continued on next page) *Not available
27 H
9/02