DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ST72324K4B6 View Datasheet(PDF) - STMicroelectronics

Part Name
Description
Manufacturer
ST72324K4B6 Datasheet PDF : 161 Pages
First Prev 131 132 133 134 135 136 137 138 139 140 Next Last
ST72324
EMC CHARACTERISTICS (Cont’d)
12.7.3 Absolute Electrical Sensitivity
Based on three different tests (ESD, LU and DLU)
using specific measurement methods, the product
is stressed in order to determine its performance in
terms of electrical sensitivity. For more details, re-
fer to the AN1181 ST7 application note.
12.7.3.1 Electro-Static Discharge (ESD)
Electro-Static Discharges (a positive then a nega-
tive pulse separated by 1 second) are applied to
the pins of each sample according to each pin
combination. The sample size depends of the
number of supply pins of the device (3 parts*(n+1)
supply pin). Two models are usually simulated:
Human Body Model and Machine Model. This test
conforms to the JESD22-A114A/A115A standard.
See Figure 70 and the following test sequences.
Machine Model Test Sequence
– CL is loaded through S1 by the HV pulse gener-
ator.
– S1 switches position from generator to ST7.
– A discharge from CL to the ST7 occurs.
– S2 must be closed 10 to 100ms after the pulse
delivery period to ensure the ST7 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
– R (machine resistance), in series with S2, en-
sures a slow discharge of the ST7.
Human Body Model Test Sequence
– CL is loaded through S1 by the HV pulse gener-
ator.
– S1 switches position from generator to R.
– A discharge from CL through R (body resistance)
to the ST7 occurs.
– S2 must be closed 10 to 100ms after the pulse
delivery period to ensure the ST7 is not left in
charge state. S2 must be opened at least 10ms
prior to the delivery of the next pulse.
Absolute Maximum Ratings
Symbol
VESD(HBM)
VESD(MM)
Ratings
Electro-static discharge voltage
(Human Body Model)
Electro-static discharge voltage
(Machine Model)
Conditions
TA=+25°C
TA=+25°C
Maximum value 1) Unit
2000
V
200
Figure 70. Typical Equivalent ESD Circuits
S1
R=1500
S1
HIGH VOLTAGE
PULSE
GENERATOR
CL=100pF
ST7
HIGH VOLTAGE
S2
PULSE
GENERATOR
HUMAN BODY MODEL
Notes:
1. Data based on characterization results, not tested in production.
ST7
CL=200pF
S2
MACHINE MODEL
131/161

Share Link: 