STLC5412
Table 7a: RXACT (indication) and TXACT (command) codes
CODES
C4 C3 C2 C1
0
0 0 00
1
0 0 01
2
0 0 10
3
0 0 11
4
0 1 00
5
0 1 01
6
0 1 10
7
0 1 11
8
1 0 00
9
1 0 01
A
1 0 10
B
1 0 11
C
1 1 00
D
1 1 01
E
1 1 10
F
1 1 11
NT
(GCI or MW, NON AUTO-MODE)
RXACT
(indications)
TXACT
(commands)
DP/LSD
PUP (1)
EIU
RES
–
SP1
–
RDT
EI
EI
–
PDN
–
–
–
QM
AP
AR
–
–
–
–
–
SP3
AI
AI
–
–
–
AIL
DI
DI
Note:
(1) ONLY IN SLAVE MODE. IN GCI MASTER MODE, SET BX PIN TO ”0” TO DO A PUP..
LT
(GCI or MW, NON AUTO-MODE)
RXACT
(indications)
TXACT
(commands)
–
PUP/DR
EIU
RES
–
SP1
–
RDT
EI
FA0
–
PDN
UAI
UAR
–
QM
AP
AR
–
–
–
ARL
–
SP3
AI
AI
–
–
–
–
DI
DI
CODES
C4 C3 C2 C1
0
0 0 00
1
0 0 01
2
0 0 10
3
0 0 11
4
0 1 00
5
0 1 01
6
0 1 10
7
0 1 11
8
1 0 00
9
1 0 01
A
1 0 10
B
1 0 11
C
1 1 00
D
1 1 01
E
1 1 10
F
1 1 11
(1) ONLY IN SLAVE MODE.
NTRR
(GCI or MW, NON AUTO-MODE)
RXACT
(indications)
TXACT
(commands)
DP/LSD
PUP (1)
EIU
RES
–
SP1
–
RDT
EI
EI
–
PDN
UAP
UAI
–
QM
AP
AR
–
–
–
–
–
SP3
AI
AI
–
–
–
–
DI
DI
LTRR
(GCI or MW, NON AUTO-MODE)
RXACT
(indications)
TXACT
(commands)
–
PUP/DR
EIU
RES
–
SP1
–
RDT
EI
FA0
–
PDN
UAI
UAR
–
QM
AP
AR
–
–
–
ARL
–
SP3
AI
AI
–
–
–
–
DI
DI
38/74