STM32F050xx
Electrical characteristics
6.3.7
Internal clock source characteristics
The parameters given in Table 33 are derived from tests performed under ambient
temperature and supply voltage conditions summarized in Table 15: General operating
conditions. The provided curves are characterization results, not tested in production.
High-speed internal (HSI) RC oscillator
Table 33. HSI oscillator characteristics(1)
Symbol
Parameter
Conditions
fHSI
TRIM
DuCy(HSI)
ACCHSI
tsu(HSI)
Frequency
HSI user trimming step
Duty cycle
Accuracy of the HSI
oscillator (factory
calibrated)
HSI oscillator startup
time
TA = –40 to 105 °C
TA = –10 to 85 °C
TA = 0 to 70 °C
TA = 25 °C
IDDA(HSI)
HSI oscillator power
consumption
1. VDDA = 3.3 V, TA = –40 to 105 °C unless otherwise specified.
2. Guaranteed by design, not tested in production.
3. Data based on characterization results, not tested in production.
Min Typ
-
8
-
-
45(2)
-
–3.8(3)
-
–2.9(3)
-
–2.3(3)
-
–1
-
1(2)
-
Max
1(2)
55(2)
4.6(3)
2.9(3)
2.2(3)
1
2(2)
Unit
MHz
%
%
%
%
%
%
µs
-
80 100(2) µA
Figure 16. HSI oscillator accuracy characterization results
-!8
-).
4! ; #=
-36
Doc ID 023683 Rev 1
57/97