STPIC44L02
Figure 15 : Normal Operation
Figure 16 : Shorted Load Condition (Deglitch Time)
OPEN LOAD
The STPiC44L02 monitors the drain of each
power FET for open circuit conditions that may
exist. The 60µA current source is provided to
monitor open load fault conditions. Open-load
faults are only detected when the power FET is
turned off. When load impedance is open or
substantially high, the 60µA current source has
adequate drive to pull the drain of T1 below the
fault reference threshold on the detection circuit.
Unused DRAIN0-DRAIN3 inputs must be
connected to VBAT through a pull-up resistor to
prevent false reporting of open-load fault
conditions. The on-board deglitch timer starts
running when the STPiC44L02, gate output to the
power FET transitates to the off state. The timer
provides a 60ms deglitch time, T(STBFM), to allow
the drain voltage to stabilize after the powerFET
has been turned off. The deglitch time is only
enabled for the first 60ms after the FET has been
14/21