2.5.3. FSK/OOK Mode Receiver
All receiver tests are performed with RxBw = 10 kHz (Single Side Bandwidth) as programmed in RegRxBw, receiving a
PN15 sequence. Sensitivities are reported for a 0.1% BER (with Bit Synchronizer enabled), unless otherwise specified.
Blocking tests are performed with an unmodulated interferer. The wanted signal power for the Blocking Immunity, ACR,
IIP2, IIP3 and AMR tests is set 3 dB above the receiver sensitivity level.
Table 8 FSK/OOK Receiver Specification
Symbol
RFS_F_LF
RFS_F_HF
RFS_O
CCR
ACR
BI_HF
BI_LF
Description
Conditions
Min
Direct tie of RFI and RFO pins,
shared Rx, Tx paths FSK sensitiv-
ity, highest LNA gain.
Bands 2&3
FDA = 5 kHz, BR = 1.2 kb/s
FDA = 5 kHz, BR = 4.8 kb/s
FDA = 40 kHz, BR = 38.4 kb/s*
FDA = 20 kHz, BR = 38.4 kb/s**
FDA = 62.5 kHz, BR = 250 kb/s***
-
-
-
-
-
FDA = 5 kHz, BR = 1.2 kb/s
-
Split RF paths, the RF switch
FDA = 5 kHz, BR = 4.8 kb/s
-
insertion loss is not accounted for. FDA = 40 kHz, BR = 38.4 kb/s*
-
Bands 2&3
FDA = 20 kHz, BR = 38.4 kb/s**
-
FDA = 62.5 kHz, BR = 250 kb/s***
-
Direct tie of RFI and RFO pins,
shared Rx, Tx paths FSK sensitiv-
ity, highest LNA gain.
Band 1
FDA = 5 kHz, BR = 1.2 kb/s
FDA = 5 kHz, BR = 4.8 kb/s
FDA = 40 kHz, BR = 38.4 kb/s*
FDA = 20 kHz, BR = 38.4 kb/s**
FDA = 62.5 kHz, BR = 250 kb/s***
-
-
-
-
-
Split RF paths, LnaBoost is turned
on, the RF switch insertion loss is
not accounted for.
Band 1
FDA = 5 kHz, BR = 1.2 kb/s
FDA = 5 kHz, BR = 4.8 kb/s
FDA = 40 kHz, BR = 38.4 kb/s*
FDA = 20 kHz, BR = 38.4 kb/s**
FDA = 62.5 kHz, BR = 250 kb/s***
-
-
-
-
-
OOK sensitivity, highest LNA gain BR = 4.8 kb/s
-
shared Rx, Tx paths
BR = 32 kb/s
-
Co-Channel Rejection, FSK
-
Adjacent Channel Rejection
FDA = 5 kHz, BR=4.8kb/s
Offset = +/- 25 kHz or +/- 50kHz
Band 1 -
Band 2 -
Band 3 -
Offset = +/- 1 MHz
-
Blocking Immunity, Band 1
Offset = +/- 2 MHz
-
Offset = +/- 10 MHz
-
Offset = +/- 1 MHz
-
Blocking Immunity, Bands 2&3
Offset = +/- 2 MHz
-
Offset = +/- 10 MHz
-
Typ
-121
-117
-107
-108
-95
-123
-119
-109
-110
-97
-119
-115
-105
-105
-92
-123
-119
-109
-109
-96
-117
-108
-9
50
56
60
71
76
84
71
72
78
Max Unit
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dBm
- dB
- dB
- dB
- dB
- dB
- dB
- dB
- dB
- dB
- dB