TDA7564B
10 Examples of bytes sequence
Examples of bytes sequence
1 - Turn-on diagnostic - Write operation
Start Address byte with D0 = 0 ACK IB1 with D6 = 1 ACK IB2 ACK STOP
2 - Turn-on diagnostic - Read operation
Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP
The delay from 1 to 2 can be selected by software, starting from 1 ms
3a - Turn-on of the power amplifier with 26dB gain, mute on, diagnostic defeat, High eff.
mode both channels.
.
Start Address byte with D0 = 0 ACK
IB1
ACK
IB2
ACK STOP
X000000X
XXX1X011
3b - Turn-off of the power amplifier
Start Address byte with D0 = 0 ACK
4 - Offset detection procedure enable
IB1
ACK
IB2
ACK STOP
X0XXXXXX
XXX0XXXX
Start
Address byte with D0 = 0
ACK
IB1
ACK
IB2
ACK STOP
XX1XX11X
XXX1X0XX
5 - Offset detection procedure stop and reading operation (the results are valid only for the
offset detection bits (D2 of the bytes DB1, DB2, DB3, DB4)
.
Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP
The purpose of this test is to check if a D.C. offset (2V typ.) is present on the outputs,
produced by input capacitor with anomalous leakage current or humidity between pins.
The delay from 4 to 5 can be selected by software, starting from 1ms
6 - Current detection procedure start (the AC inputs must be with a proper signal that
depends on the type of load)
Start Address byte with D0 = 0 ACK
IB1
ACK
IB2
ACK STOP
XX01111X
XXX1X1XX
Current detection reading operation (the results valid only for the current sensor detection
bits - D5 of the bytes DB1, DB2, DB3, DB4)
.
Start Address byte with D0 = 1 ACK DB1 ACK DB2 ACK DB3 ACK DB4 ACK STOP
During the test, a sinus wave with a proper amplitude and frequency (depending on the
loudspeaker under test) must be present. The minimum number of periods that are
needed to detect a normal load is 5.
The delay from 6 to 7 can be selected by software, starting from 1ms.
29/34