TDA7567PD
Electrical specifications
Table 4. Electrical characteristics (continued)
Symbol
Parameter
Test condition
Pvs
Pnop
Short to Vs det. (Above this
limit, the output is considered
in short circuit to VS)
Normal operation thresholds.
(Within these limits, the
output is considered without
faults).
Power amplifier in mute or play,
one or more short circuits
protection activated
LSC
Shorted load det.
Power amplifier mode
Line driver mode
VO
Offset detection
Power amplifier in play,
AC Input signals = 0
INLH
Normal load current detection VO < (VS - 5)pk IB2 (D7) = 0
INLL
Normal load current detection VO < (VS - 5)pk IB2 (D7) = 1
IOLH
Open load current detection VO < (VS - 5)pk IB2 (D7) = 0
IOLL
Open load current detection VO < (VS - 5)pk IB2 (D7) =1
I2C bus interface
SCL
Clock frequency
-
VIL
Input low voltage
-
VIH
Input high voltage
-
Min. Typ. Max. Unit
Vs -1.2 -
-
V
1.8
- Vs -1.8 V
-
-
0.5
Ω
-
-
1.5
Ω
±1.5
±2 ±2.5
V
500
-
-
mA
300
-
-
mA
-
-
250 mA
-
-
125 mA
-
-
400 kHz
-
-
1.5
V
2.3
-
-
V
Figure 4. ITU R-ARM frequency response, weighting filter for transient pop
Output attenuation (dB)
10
0
-10
-20
-30
-40
-50
10
100
1000
10000
100000
Hz
AC00343
Doc ID 16903 Rev 1
11/30