TS7514
DC AND OPERATING CHARACTERISTICS (continued)
Electrical characteristics are guaranteed over the complete temperature range, with typical load unless
otherwise specified. Typical values are given for : V+ = +5V, V− = -5V and room temperature = 25oC
Symbol
Parameter
Test Conditions Min. Typ. Max. Unit
RECEIVE TRANSFER - GENERAL CHARACTERISTICS
Absolute Filter Gain for :
0dB programmed
6dB programmed
12dBprogrammed
RDS Signal Detection Level Relative to Programmed Value
RHY Hysteresis Value
Signal Level (loop 3) at Reception Input
– 0.5 –
+ 5.5 –
+ 11.5 –
– 0.5 –
–2 –
– 40 – 35
+ 0.5
+ 6.5
12.5
+ 0.5
–
– 33
dB
dB
dB
dBm
LINE MONITORING - GENERAL CHARACTERISTICS (load conditions : RL = 10kΩ, CL = 50pF)
ATT Absolute Gain for 0dB Programmed
–
0
– dB
RAT Attenuation Relative to Programmed Value
-
Attenuation for Programmed Value
– 1 – + 1 dB
70
–
dB
FS Buzzer Signalling Frequency
– 2982 – Hz
Signalling Frequency Amplitude at 0.42VPP Programmed
0.38 0.42 0.46 VPP
14/19