DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

XE8802MI000 View Datasheet(PDF) - Semtech Corporation

Part Name
Description
Manufacturer
XE8802MI000 Datasheet PDF : 193 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
XE8802 Sensing Machine Data Acquisition MCU
with ZoomingADC™ and LCD driver
2.1 Absolute maximum ratings
Table 2-1. Absolute maximal ratings
Min.
Max.
Note
Voltage applied to VBAT with respect to VSS
-0.3
6.0
V
Voltage applied to VPP with respect to VSS
VBAT-0.3
12
V
Voltage applied to all pins except VPP and VBAT
VSS-0.3 VBAT+0.3 V
Storage temperature (ROM device or unprogrammed
-55
150
°C
flash device)
Storage temperature (programmed flash device)
-40
85
°C
Stresses beyond the absolute maximal ratings may cause permanent damage to the device. Functional operation
at the absolute maximal ratings is not implied. Exposure to conditions beyond the absolute maximal ratings may
affect the reliability of the device.
2.2 Operating range
Table 2-2. Operating range for the flash device
Voltage applied to VBAT with respect to VSS
Voltage applied to VBAT with respect to VSS during
the flash programming
Voltage applied to VPP with respect to VSS
Voltage applied to all pins except VPP and VBAT
Operating temperature range
Capacitor on VREG (flash version)
Capacitor on VMULT
Min.
2.4
4.5
VBAT
VSS
-40
0.8
1.0
Max.
5.5
5.5
11.5
VBAT
85
1.2
3.0
Note
V
V1
V
V
°C
µF 2
nF 3
1. During the programming of the device the temperature must be between 10°C and 40°C.
2. The capacitor on VREG is mandatory.
3. The capacitor on VMULT is optional. The capacitor has to be present if the multiplier is enabled. The
multiplier has to be enabled if VBAT<3.0V.
Table 2-3. Operating range for the ROM device
Min. Max.
Note
Voltage applied to VBAT Acquisition VREG by-
1.2
with respect to VSS
chain off
passed
VREG on
1.5
Acquisition VMULT on
2.4
chain on
VMULT off
3.0
5.5
V2
5.5
V
5.5
V
5.5
V
Voltage applied to all pins except VPP and VBAT
Operating temperature range
Capacitor on VREG
Capacitor on VMULT
VSS
VBAT
V
-40
125
°C
0.1
1.2
µF 1
1.0
3.0
nF 3
1. The capacitor may be omitted when VREG is connected to VBAT.
2. The voltage reference for the LCD drivers starts operating at 1.5 V.
3. The capacitor on VMULT is optional. The capacitor has to be present if the multiplier is enabled. The
multiplier has to be enabled if VBAT<3.0V.
© Semtech 2006
www.semtech.com
2-2