STAP16DPPS05
7.5
Auto power-saving
Error detection mode functionality
The auto power-saving feature minimizes the quiescent current if no active data is detected
on the latches and auto powers-up the device as the first active data is latched.
Figure 23: Auto power-saving feature
Conditions:
Temp. = 25 °C, VDD = 3.3 V, Vin = VDD, VLed = 3.0 V, Iset = 20 mA
Ch1 (yellow) = CLK, Ch2 (blue) = SDI, Ch3 (purple) = LE/DM1, Ch4 (green) = IDD
Idd consumption:
Idd (normal operation) = 2.93 mA
Idd (shutdown condition) = 170 µA
Figure 24: Auto power-saving feature: first output TON
Conditions:
Temp. = 25 °C, VDD = 3.3 V, Vin = VDD, VLed = 3.0 V, Iset = 20 mA
Ch1 (yellow) = CLK, Ch2 (blue) = SDI, Ch3 (purple) = LE/DM1, Ch4 (green) = IDD
When the device goes from auto power-saving to normal operating condition, the
first output switching ON shows the TON condition as seen in the plot above.
DocID024306 Rev 7
23/29