STM6600, STM6601
7
DC and AC characteristics
DC and AC characteristics
This section summarizes the operating measurement conditions and the DC and AC
characteristics of the device. The parameters inTable 5 that follow are derived from tests
performed under the measurement conditions summarized in Table 4. Designers should
check that the operating conditions in their circuit match the operating conditions when
relying on the quoted parameters.
Table 4. Operating and AC measurement conditions
Parameter
Condition
Unit
VCC supply voltage
Ambient operating temperature (TA)
Input rise and fall times
1.6 to 5.5
V
–40 to 85
°C
≤_5
ns
Symbol
Parameter
Table 5. DC and AC characteristics
Test condition(1)
Min.
VCC Supply voltage
ICC Supply current
1.6
VCC = 3.6 V, no load
Standby mode, enable
deasserted, VCC = 3.6 V
2.40
3.00
Power-on lockout voltage
VTH+ (see Table 10 for detailed
3.20
listing)
3.29
3.39
VHYST
Threshold hysteresis (see
Table 10 for detailed listing)
VTH–
Forced power-off voltage
(see Table 10 for detailed
listing)
tTH–
Undervoltage detection to
INT delay
VCC ≥ 2.0 V
20
1.4
Blanking period (see
tON_BLANK
Table 10 for detailed
listing)(3)
5.6
11.2
RST assertion to EN (EN)
assertion delay during
power-up
VCC = 3.6 V
Typ.(2)
6.0
0.6
2.50
3.10
3.30
3.40
3.50
200
500
Max. Unit
5.5 V
8.0 µA
1.0 µA
2.60
3.20
3.40 V
3.51
3.61
mV
VTH+ – VHYST
V
32
44 ms
2.2
3.0
8.8
12.0 s
17.6
24.0
100
ns
DocID15453 Rev 12
39/52
51